Home > Knowledge > Content

VF5+ Electronic Module manual English version

Nov 21, 2019

Instructions DOC-FE.IE.IN.xxxxxx.EN VF5+ Electronic Module Version: 0.0 INDEX ● CONNECTIONS........................................................................................................................................................................................3 ● PROGRAMMING.......................................................................................................................................................................................4 ● INPUTS......................................................................................................................................................................................................5 ● TROUBLESHOOTING DURING THE AUTOADJUSTMENT....................................................................................................................9 ● NORMAL REGULATION WITH THE LIFT CONTROLLER.....................................................................................................................10 ● POWER FAILURES.................................................................................................................................................................................11 ● TEST OF THE PHOTOCELL...................................................................................................................................................................12 ● TROUBLESHOOTING.............................................................................................................................................................................13 ● REFERENCE DATA................................................................................................................................................................................14 ● DECLARATION OF CONFORMITY.........................................................................................................................................................16 Fermator Group • www.fermator.com Pág. 2 / 15Instructions DOC-FE.IE.IN.xxxxxx.EN VF5+ Electronic Module Version: 0.0 Fermator Group • www.fermator.com Pág. 3 / 15Instructions DOC-FE.IE.IN.xxxxxx.EN VF5+ Electronic Module Version: 0.0 PROGRAMMING The VF may be programmed using the DIP switches on the front of the unit. If any change is made to any of the above switch selections, the main supply of the VF unit MUST be switched OFF and ON again to read the new programming. The switches functions are:  1.- 1 & 2 Inputs ON: 1 Input. The door control unit will be controlled by a single input. Any voltage between 12 V DC to 60 V DC or 100 V AC to 230 V AC applied between terminals 8 & 10 will close the doors. Without input active  the door remains opened. Open input is not used.  OFF: 2 Inputs. The door control module will be controlled by two independent inputs. Any voltage between 12 V DC  to 60 V DC or 100 V AC to 230 V AC applied between terminals 8 & 10 will cause the doors to close. And between terminals 10 & 12 will cause the doors to open. In the absence of a signal, the doors  will remain static. If both inputs are applied then the open signal has priority. 2.- Automatic / Semiautomatic ON: Automatic. Operators with skate (automatic landing). In this case a special movement is made for locking and  unlocking the skate. OFF: Semiautomatic. Operators without skate (Semiautomatic landing door). 3.- Rotation sense ON: Look at the picture:  − Skate fixed on the top side of the belt and the motor on the right side. − Skate fixed on the bottom side of the belt and the motor on the left side. OFF: Look at the picture: − Skate fixed on the bottom side of the belt and the motor on the right side. − Skate fixed on the top side of the belt and the motor on the left side. 4.- Master and Slave ON: Master. The door control unit will execute instructions directly. Example: photocell activation will cause the doors to re-open immediately without control of the door control unit. OFF: Slave. There is no automatic reopen movements. The doors will only react to instruction given by the main  lift controller. Example: with the photocell activated the unit will send a signal to the main lift  controller via the PHOTOCELL output (36, 37, 38). Then, the main lift controller must remove the  close signal and put the open signal. Fermator Group • www.fermator.com Pág. 4 / 15Instructions DOC-FE.IE.IN.xxxxxx.EN VF5+ Electronic Module Version: 0.0 INPUTS POWER INPUTS 230 VOLTS SINGLE PHASE AC (5, 6, 7) The circuit has been designed to operate on a mains supply of 230 V AC (+10%,-15%, 50 or 60 Hz). The unit will consume on average approximately 1 ampere from the supply. It is important that the Door Operator Module has a GOOD EARTH CONNECTION. The VF5+ incorporates a soft-start system to control the bulk capacitors charge and prevent short circuits. The circuit has been designed to pass the industrial level in immunity test according to the norm EN 12016:2004. CONTROL INPUTS (8, 9, 10, 11, 12) The circuit can work with external voltage inputs or internal voltage input (voltage free contact). 12.- Opening Signal Is a signal that orders the door to open. The tension to apply could be from 12 V DC to 60 V DC or  100 V AC to 230 V AC, with an external supply between this input and common (10). 11.- 0 Volts Is the opposite pole to 12 V, in the case of using internal voltage it should be connected to common  input. 10.- Common Is the reference used for the opening and closing signal. 9.- 12 Volt Isolated 12 Volts output available to control the door via a voltage free contact. Features are: a) This supply must only be used for this purpose. b) This contact must be isolated from any other power supply. 8.- Close signal This signal is used for ordering to close the door.